QG-3000 TEM Stainer

QG-3000 Automated TEM Stainer

Find Your Local Dealer

For Automated Staining of TEM Samples
 

F a s t
R e l i a b l e
R e p r o d u c i b l e

While Minimizing...

      Sample Contamination
      Solution Waste

 
                                                                     

 

 

Features
  • Closed flow system provides clean conditions and exclusion of air
  • Staining procedures are reliable and reproducible
  • Exposure to staining solutions is minimized
  • Extremely low operation costs
  • Individual staining procedures may be easily configured
  • Simple maintenance due to freely accessible tubing and valves
  • Patented rotatable staining chamber

The Need

Since most organic materials produce only low-contrast results in transmission electron microscopy (TEM), staining procedures are needed to increase the image contrast.

Staining involves treatment with solutions that contain heavy metal salts (e.g. uranium, lead, osmium or tungsten), which attach to certain cellular components (peptides, lipids, nucleic acids etc.). These salts contain ions with a high number of protons. When the electron beam passes through a sample area decorated with such ions, it increases image contrast.


Problems With Manual Staining

All TEM preparation procedures require very clean conditions, as even minor contaminations are visible in the high magnifications of the TEM.

Lead citrate solutions are very sensitive to exposure to carbon dioxide, because this results in a precipitation of fine particles of lead carbonate, which instantly damages the sample. Therefore, the staining process must exclude atmospheric air.

In many labs, TEM staining is accomplished by hand. The grids are placed on small drops of staining solutions and washed between and after staining steps. It is very difficult to avoid contamination. Many samples are discarded.

Processing grids by hand is also very time consuming, and the number of grids that can be stained simultaneously is limited. Furthermore, manual staining increases the risk of exposing the user to potentially harmful substances.


Solution: QG-3000

The QG-3000 automatic stainer increases both the staining quality and the yield by minimizing contamination, while saving time and reducing waste.

Through the unit’s unique design, which uses a patented rotatable staining chamber, peristaltic pump, and pinch valves, the solutions are isolated to the tubing and grid chamber. Liquids flow in only one direction. In addition to minimizing contamination, this design significantly reduces the time and waste associated with other techniques.


Open, Flexible Design

All components exposed to the staining solutions are easy to replace. Maintenance is simple and may be performed by the user. Extra input and output channels, freely programmable routines and an exchangeable grid chamber allows the realization of various laboratory tasks (e.g. graded ethanol series).

 

Specifications
Copyright © 2010 Boeckeler Instruments. All rights reserved. Functional Design and Architecture Copyright © 2010 Chapman Net Systems, Inc.. All rights reserved.